With the Pressure Gauge Wizard you will be able to create industry standard Pressure gauges in a few minutes by just entering some key values.

The Temperature Gauge Wizard shares most of its settings with the Pressure Gauge Wizard, so this page describes them for both wizards.

The wizard settings are organized into four sections after the Wizard View option: Gauge Wizard, All Scales, and one or two per-scale sections depending on whether Dual Scale is enabled. The following options will be available for both the Temperature and Pressure wizards.

Industrial gauge wizards shared options

SettingDescription
Dual ScaleEnables two measurement scales (e.g., °C/°F or Bar/PSI) on the same gauge for dual readings.
Scale SideIn or Out, for a single scale only. Sets whether the ticks and numbers sit on the inner or the outer side of the arc line. It is hidden while Dual Scale is on, since both sides are used. With Out, the scale still stays inside Outer Radius.
Main ScaleWhen Dual Scale is enabled, selects which scale (Inner or Outer) is the main scale. The main scale settings section will appear first, and the secondary scale section will follow with additional edge matching settings.
Dual ArcWith Dual Scale on, if enabled, each scale will have its own solid edge arc, otherwise they will share the same.
Outer RadiusThe outer limit of everything the wizard generates, so the generated layers never extend past it. See Outer Radius and Scale Edges.
Inner Scale EdgeThe radius of the inner scale’s arc line edge, its outer edge.
Outer Scale EdgeWith Dual Scale and Dual Arc both on only. The radius of the outer scale’s arc line edge, its inner edge.
Arc SpacingWith Dual Scale and Dual Arc both on only. The distance between the inner and outer arcs to ensure clear separation and readability.
Arc AngleThe arc angle of the main scale, from start to end angles, by default symmetrical about the vertical axis.
Angle OffsetOffset added to Start Angle to allow for asymmetrical gauge scale arcs.
Start AngleThe start angle of the main scale. Editing it moves only the start of the arc and keeps its end, and Arc Angle and Angle Offset update to match.
End AngleThe end angle of the main scale. Editing it moves only the end of the arc and keeps its start, and Arc Angle and Angle Offset update to match.

Editing the Start Angle and End Angle directly makes it easier to line up several wizard scales. A change leaving less than 10 degrees between the two is ignored.

Outer Radius is the outer limit of everything the wizard generates, on preset and free gauges alike, so the generated layers never extend past it. On a gauge with a size preset it starts at the preset’s working radius. On a free gauge that already has printable layers it starts at their outer extent, with fonts and tick sizes scaled to match. On an empty free gauge it starts at the default working radius.

Directly under it, Inner Scale Edge and, with Dual Scale and Dual Arc both on, Outer Scale Edge give the radius of each scale’s arc line edge, the Inner Scale’s outer edge and the Outer Scale’s inner edge. These are the lines to match against an existing arc, and all the radius fields use the current measurement unit.

  • Each edge field moves only its scale edge. The two edges never cross and sit at most 50 px apart.
  • When Dual Scale and Dual Arc are both on, Arc Spacing shows the gap between the two edges. Editing it moves the outer edge only.
  • With Dual Arc off, the shared arc line is drawn above both scales’ tickmarks, and the outer scale’s numbers keep the same Text Spacing from their ticks as the inner scale’s.
  • Editing Outer Radius, or switching Dual Scale or Scale Side, places the edges again from the Outer Radius.

The settings in this section apply to both scales simultaneously.

Industrial gauge wizard all scales options

SettingDescription
FontAllows you to select the font that will be used for all the text elements of the gauge.
Font SizeSets the font size for all the text elements of the gauge.
Text SpacingSets the distance between the tickmarks and the scale numbers.
Major LengthSets the length of the major tickmarks.
Major WidthSets the width of the major tickmarks.
Mid LengthSets the length of the mid tickmarks.
Mid WidthSets the width of the mid tickmarks.
Minor LengthSets the length of the minor tickmarks.
Minor WidthSets the width of the minor tickmarks.
Caps LengthSets the relative length of the major tickmark head caps, where 1 is the whole length of the major tickmarks. Disabled when no scale has Tick Caps enabled.
Caps WidthSets the width of the major tickmark head caps. Disabled when no scale has Tick Caps enabled.
Zero WidthSets the width of the zero band marker over the zero major tickmark. Disabled when no scale has Zero Band enabled.
Arc Line WidthSets the width of the scale arc edge line.

Pressure gauge wizard options

On the Pressure Wizard you must select the pressure unit of the scales. When using two scales, the outer scale will default to a pressure unit that is commonly used as counterpart to the unit used on the inner scale.

Industrial gauge wizard scale options

When Dual Scale is enabled, two scale sections will be shown: the Main Scale section first, followed by the Secondary Scale section. The secondary scale may have some parameters disabled as those will be set by the conversion from the main scale values.

SettingDescription
Scale UnitSelects the measurement unit for this scale.
Scale StartSpecifies the first scale value.
Scale EndSpecifies the last scale value.
Major IntervalSpecifies the major interval value at which major tickmarks and scale values should be set.
Text SkipBy default, the numeric scale values match the positions of the major tickmarks, but this option allows us to skip some major tickmarks if these are not meant to match.
Mid TickEnables the mid tickmark between major tickmarks. The mid tick will be longer than the other minor tickmarks to stand out.
Minor TicksSets the number of minor ticks between major tickmarks. When Mid Tick is off the available values are: 0, 4, 9. When Mid Tick is on the available values are: 1, 3, 9, 19.
Tick CapsIf enabled, the major tickmarks will have wide head caps to make them stand out.
Zero BandEnables the zero band marker over the zero major tickmark. The field stays visible but disabled when a zero band does not apply to the scale values.
ColorSets the color to be used by all the layers that make up this scale.

The Secondary Scale section includes additional Start and End settings that define how to calculate the edge values of the secondary scale relative to the main scale. These settings will automatically calculate the secondary scale edge values by matching the main scale based on one of the following rules:

Double scale edge out

  • In - The secondary scale will be set to the value of the main scale’s edge value, converted to the secondary scale’s unit that is the closest multiple of the Major Interval, and lies within the arc angle range of the main scale arc.

Double scale edge in

  • Flush - The secondary scale will be set to the value of the main scale’s edge value converted to the secondary scale’s unit that is the closest full value.

Double scale edge flush

  • Out - The secondary scale will be set to the value of the main scale’s edge value, converted to the secondary scale’s unit that is the closest multiple of the Major Interval, and lies outside the arc angle range of the main scale arc.

Double scale edge out